| Item | Specification |
|---|---|
| Product Name | YP-P16 / YP-P32 / YP-P48 |
| Appearance | |
| Dimensions (W×D×H) | 235 mm × 385 mm × 175 mm |
| Weight | 5.6 kg / 5.7 kg / 5.8 kg |
| Electrical Parameters | |
| Power | ~220 V / 50 Hz, 255 W |
| Data Interface | USB 2.0 × 2 (two on the right side) |
| Environmental Parameters | |
| Operating Conditions | Temperature: 10–30 °C, Humidity: 20%–80% |
| Transportation & Storage Conditions | Temperature: –20–55 °C, Humidity: 20%–80% |
| Altitude | < 2500 meters |
| Noise Level | A-weighted, < 60 dB |
| Sample Parameters | |
| Sample Capacity | 16 × 0.2 mL / 32 × 0.2 mL / 48 × 0.2 mL |
| Tube Type | Single tube, 8-strip tube |
| Sample Volume | 15–100 μL |
| Temperature Characteristics | |
| Heating/Cooling Method | Semiconductor heating/cooling |
| Temperature Range | 4 °C–99 °C |
| Max. Heating Rate | ≥ 3.5 °C/s |
| Avg. Heating Rate | ≥ 2.5 °C/s |
| Max. Cooling Rate | ≥ 3.5 °C/s |
| Avg. Cooling Rate | ≥ 2.5 °C/s |
| Temperature Control Accuracy | ≤ ±0.01 °C |
| Temperature Accuracy | ≤ ±0.1 °C |
| Temperature Uniformity | ≤ ±0.3 °C |
| Optical Characteristics | |
| Number of Fluorescence Detection Channels | 2 / 4 / 4 |
| Light Emitting Device | High-brightness LED |
| Light Collection Device | High-sensitivity, high signal-to-noise ratio photodiode |
| Compatible Probes/Dyes | |
| Channel 1 | 470/520: FAM, SYBR Green |
| Channel 2 | 530/570: HEX, JOE, VIC |
| Channel 3 | 580/610: ROX, Cy3.5, Texas Red |
| Channel 4 | 630/670: Cy5 |
| Detection Sensitivity | 1 copy |
| Linear Detection Range | 10⁰–10¹⁰ copies |
| Linear Correlation Coefficient | ≥ 0.999 |
| Channel Crosstalk | No crosstalk |
| Detection Repeatability | ≤ 1.0% |
Basic scientific research
Pathogen detection
Meat product adulteration
GMO detection
Food safety testing
Drug development and rational drug use
Gene expression
Water monitoring
Full-Wavelength Microplate Reader: An All-Round Spectral Analysis Platform for Insight into the Microscopic World
2026-02-02Which brand is good for microbial broth concentration meters? Youyunpu D600 leads a new research experience.
2026-02-02Brand Recommendation for Handheld Portable Fluorometers: Youyunpu Fluorometers Enable Accurate and Rapid Detection
2026-02-02Which brand of full-wavelength microplate reader is good? Youyunpu leads new scientific research standards with precision and efficiency.
2026-02-02Automatic Colony Analyzer: An Intelligent Solution for Modern Microbiology Laboratories
2026-02-02How Does a Real-Time Quantitative PCR (qPCR) Detector Work? Principles and Applications in One Article
2026-02-02Microbial Limit Filtration System Manufacturer Recommendation: Youyunpu Guards the Cleanliness Bottom Line of Experiments with High Efficiency and Reliability
2026-02-02Youyunpu Fluorescent Quantitative PCR Detector Manufacturer Analysis: How Does the Technical System Support Stable Nucleic Acid Detection?
2026-02-02