+86 19963093538
Current location:HOME>PRODUCT>Specialized Instruments>Racing Pigeon Flight Performance Analyzer
Racing Pigeon Flight Performance Analyzer

Racing Pigeon Flight Performance AnalyzerYP-P32


【Introduction】:Youyunpu Optoelectronic Tech specializes in R&D & production of Racing Pigeon Flight Performance Analyzer, with custom services. Complete Racing Pigeon Flight Performance Analyzer models, high detection accuracy, trusted by customers.

Product Details

Instrument Introduction

For a long time, superior bloodlines have been regarded as a key factor in racing performance. The term "superior bloodlines" refers to specific heritable genotypes. Given that certain genes significantly influence athletic performance in racing pigeons, and with reference to authoritative literature and European testing experience combined with our innovative technologies, three key markers have been identified:
homing ability (DRD4), endurance (LDHA), and cryptochrome (CRY1). These markers provide valuable references for breeding and flight performance. Testing these indicators offers a more scientific basis for fanciers to select racing and breeding pigeons.
Our pigeon flight performance analyzer integrates the above genetic research. It can simultaneously identify:
  • Pigeon gender

  • Genotypes related to flight performance, including

    • Homing ability (DRD4)

    • Endurance (LDHA)

    • Navigation and circadian rhythm (CRY1)

Instrument Structure

The real-time fluorescent quantitative PCR system is a real-time reaction detection instrument, mainly composed of:
  1. Gene amplification thermal cycler system

  2. Real-time fluorescence detection system

  3. Microcircuit control system

  4. Computer and application software

The two core functional modules are the thermal cycler system and the real-time fluorescence detection system.
  • The gene amplification thermal cycler uses semiconductor heating and cooling to perform thermal cycling, with a working principle similar to conventional PCR instruments.

  • The fluorescence detection system consists of a fluorescence excitation unit, optical signal transmission components, a fluorescence detection unit, and a control system.

Instrument Features

  1. Compact, lightweight and portable; compatible with 0.2 mL PCR single tubes and 8-tube strips.

  2. Equipped with custom U.S. MARLOW Peltier modules and advanced semiconductor heating/cooling technology, with a maximum ramp rate of 7 °C per second and a service life of up to 1,000,000 cycles.

  3. Adopts proprietary optical detection and signal processing with automatic fluorescence background adjustment, improving sensitivity and signal-to-noise ratio for superior results.

  4. 13-second 4-channel rapid scanning with stable signal acquisition and reduced delay error.

  5. Maintenance-free long-life LED light sources; independent fluorescence channels with minimal crosstalk.

  6. Constant-current control circuit ensures smooth power output, extends Peltier lifespan and improves temperature control accuracy.

  7. Comprehensive protection including over-current and over-temperature protection.

  8. Powerful software supporting quantitative analysis, melting curve analysis and genotyping; free lifetime software updates and customization for different industries.

  9. Built-in 10-inch color touchscreen control.

Technical Specifications

ItemSpecification
Dimensions (W×D×H)235 mm × 385 mm × 175 mm
Weight5.8 kg
Power~220 V / 50 Hz, 255 W
Data Interface2 × USB 2.0
Operating Conditions10–30 °C, 20%–80% RH
Storage & Transport−20–55 °C, 20%–80% RH
Altitude< 2500 m
NoiseA-weighted, < 60 dB
Sample Capacity32 × 0.2 mL
Tube Type0.2 mL PCR single tubes, 8-tube strips
Reaction Volume15–100 μL
Heating/CoolingSemiconductor heating / cooling
Temperature Range4 °C – 99 °C
Max Heating Rate≤ 5.5 °C/s
Avg Heating Rate≥ 3.5 °C/s
Max Cooling Rate≤ 4.5 °C/s
Avg Cooling Rate≥ 2.5 °C/s
Temperature Precision≤ ±0.01 °C
Temperature Accuracy≤ ±0.1 °C
Temperature Uniformity≤ ±0.3 °C
Fluorescence Channels4
Light SourceHigh-brightness LED
DetectorHigh-sensitivity, high-SNR photodiode
Supported Probes/DyesChannel 1: 470/520 – FAM, SYBR Green
Channel 2: 530/570 – HEX, JOE, VIC
Channel 3: 580/610 – ROX, Cy3.5, Texas Red
Channel 4: 630/670 – Cy5
Detection Sensitivity1 copy
Linear Range10⁰ – 10¹⁰ copies
Correlation Coefficient≥ 0.999
Channel CrosstalkNone
Repeatability≤ 1.0%