+86 19963093538
Current location:HOME>PRODUCT>Specialized Instruments>Pigeon DNA Identification Instrument
Pigeon DNA Identification Instrument

Pigeon DNA Identification InstrumentYP-P16


【Introduction】:Youyunpu Optoelectronic Tech specializes in R&D & production of Pigeon DNA Identification Instrument, with custom services. Complete Pigeon DNA Identification Instrument models, high detection accuracy, trusted by customers.

Product Details

Product Overview

Generally, male pigeons have ZZ sex chromosomes, while female pigeons have ZW chromosomes. Pigeon gender cannot be directly determined by visual appearance, as they lack obvious sexual characteristics. However, by extracting DNA samples from pigeons for genetic testing, their gender can be accurately identified. This method takes advantage of the differences in the sex chromosomes of pigeons. Gender is determined by detecting the presence or absence of specific gene fragments.

Instrument Structure

The Pigeon / Parrot Sex Detector is a real-time reaction detection instrument, mainly composed of a gene amplification thermal cycler system, a real-time fluorescence detection system, a microcircuit control system, and a computer with application software. Among them, the two core functional modules are the thermal cycler system and the real-time fluorescence detection system.
The gene amplification thermal cycler works on a principle similar to that of conventional gene amplifiers, using semiconductor heating and cooling to complete the thermal cycling process. The fluorescence detection system mainly consists of a fluorescence excitation unit, optical signal transmission components, a fluorescence detection unit, and a control system.

Device Specifications

Dimensions (W×D×H): 235 mm × 385 mm × 175 mm
Weight: 5.6 kg
Electrical: ~220 V / 50 Hz, 255 W
Data Interface: 2 × USB 2.0 (on the right side)

Environmental Parameters

  • Operating conditions: Temperature 10–30 ℃, humidity 20%–80% RH

  • Storage & transport conditions: Temperature −20–55 ℃, humidity 20%–80% RH

  • Altitude: < 2500 m

  • Noise level: A-weighted, < 60 dB

Sample Parameters

  • Sample capacity: 16 × 0.2 mL

  • Tube type: Single tubes, 8‑tube strips, 16‑well blocks

  • Reaction volume: 15–100 μL

Thermal Performance

  • Heating/cooling method: Semiconductor heating / cooling

  • Temperature range: 4 ℃ – 99 ℃

  • Max heating rate: ≥ 3.5 ℃/s

  • Average heating rate: ≥ 2.5 ℃/s

  • Max cooling rate: ≥ 3.5 ℃/s

  • Average cooling rate: ≥ 2.5 ℃/s

  • Temperature precision: ≤ ±0.01 ℃

  • Temperature accuracy: ≤ ±0.1 ℃

  • Temperature uniformity: ≤ ±0.3 ℃

Optical Performance

  • Fluorescence channels: 2

  • Light source: High‑brightness LED

  • Detector: High‑sensitivity, high‑SNR photodiode

  • Supported probes/dyes:

    • Channel 1 (470/520): FAM, SYBR Green

    • Channel 2 (530/570): HEX, JOE, VIC

  • Detection sensitivity: 1 copy

  • Linear range: 10⁰ – 10¹⁰ copies

  • Correlation coefficient: ≥ 0.999

  • Channel crosstalk: None

  • Repeatability: ≤ 1.0%

Related Products